Okta Access Gateway 2026.10.2 Fixes Admin Console Command Execution

P2 — VALIDATE AND UPDATENot provided by the authority · 9.1 (CVSS v3.1)EXPLOITATION: NOT STATED

Quick Answer

Okta fixes CVE-2026-115547 in Access Gateway 2026.10.2. Inventory vulnerable appliances and administrators, upgrade through the supported process, validate configuration workflows, review relevant admin activity where warranted, and retain evidence.

Confirm Scope And Apply The Supported Remediation

What to do now: Inventory Access Gateway releases, Admin Console exposure, administrative identities and roles, recent configuration changes, owners, and maintenance windows. Confirm the affected release and authenticated administrative precondition; do not describe the issue as unauthenticated remote command execution. Upgrade to Access Gateway 2026.10.2 or later and review administrative access under normal identity-governance procedures. Confirm the appliance release, test representative configuration changes, review Admin Console and system logs for suspicious commands where warranted, validate protected applications, and retain evidence.

Open the authoritative advisory

Last verified: 2026-10-23 UTC. Recheck the authoritative advisory and supported distribution channel before changing production.

Scope And Authority

Product scopeOkta Access Gateway Admin Console
AdvisoryCVE-2026-115547
CVECVE-2026-115547
Authoritative release date2026-10-22
Authority revision date2026-10-22
Affected versionsOkta Access Gateway releases before 2026.10.2; exploitation requires an authenticated user with administrative access to the Admin Console.
Fixed versionOkta Access Gateway 2026.10.2 or later
CVSS base score9.1 (CVSS v3.1)
CVSS severityNot provided by the authority
Exploitation statusOkta does not state that this issue is being maliciously exploited.; no exploitation claim is inferred.

What Changed

Okta corrected input validation in configuration values that could let an authenticated administrator execute system commands in the Access Gateway service-account context.

What To Validate Now

  1. Inventory. Inventory Access Gateway releases, Admin Console exposure, administrative identities and roles, recent configuration changes, owners, and maintenance windows.
  2. Establish applicability. Confirm the affected release and authenticated administrative precondition; do not describe the issue as unauthenticated remote command execution.
  3. Remediate. Upgrade to Access Gateway 2026.10.2 or later and review administrative access under normal identity-governance procedures.
  4. Validate. Confirm the appliance release, test representative configuration changes, review Admin Console and system logs for suspicious commands where warranted, validate protected applications, and retain evidence.
  5. Retain evidence. Preserve asset and owner identifiers, the applicability decision, before-and-after versions, change approval, installation output, validation results, and any exception or rollback record.

Operational Cautions

Okta publishes a 9.1 CVSS v3 score but no textual severity on the advisory. An administrative account is required, so investigation should focus on actual console access and changes.

Evidence To Retain

  • Exact product, release stream, package or application version, enabled feature, environment, and accountable owner.
  • UTC timestamps, authority revision, approved change record, installer or package-manager output, and resulting version.
  • Relevant logs and monitoring evidence, test results, exceptions, compensating controls, and rollback decisions.

Related TechGeeks Resources

Authoritative References

Correction policy: If the authority changes affected versions, fixed versions, severity, exploitation information, mitigations, or required action, TechGeeks will update this notice and its verification date.